MEDIUM TEMPERATURE WATER-TO-WATER HEAT PUMPS 30XWHP-ZE/30XWHV-ZE
Physical data
30XWHP ZE 30XWHP ZE0301 30XWHP ZE0401 30XWHP ZE0451 30XWHP ZE0551 30XWHP ZE0601
Heating
Performance Information Heating Capacity* Heating Efficiency Maximum hot water temperature Number of Refrigerant Circuit Operating/Shipping Weight Unit Dimensions Electrical Information Unit Voltage: Standby Power: Power Factor: Amps (Un) Circuit 1 Maximum Current Start Up Current Current at Eurovent Conditions Circuit 2 Maximum Current Start Up Current Current at Eurovent Conditions A A A ---------------A A A 130 303 87 176 414 109 196 414 123 239 587 146 263 587 162 V-Ph-Hz 400(+/-10%) -3-50 kW -0,05 0,88 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 400(+/-10%) -3-50 0,05 0,90 COP kW kW/kW °C -kg LxWxH mm 321 6,25 70 1 2072/1953 2724/927 /1617 449 6,72 70 1 2981/2763 3059/936/ 1743 510 6,64 70 1 3020/2802 3059/936/ 1743 648 6,83 70 1 3912/3593 3290/1065/ 1950 695 6,63 70 1 3947/3628 3290/1070/ 1950
30XWHP ZE
30XWHP ZE0651
30XWHP ZE0801
30XWHP ZE0901
30XWHP ZE1001
30XWHP ZE1101
Heating
Performance Information Heating Capacity* Heating Efficiency COP kW kW/kW °C -kg mm 761 6,66 70 1 3965/3646 3290/1070/ 1950 916 6,73 70 2 6872/6218 4795/1039/ 1997 400(+/-10%) -3-50 0,05 0,89 1019 6,79 70 2 6950/6296 4795/1039/ 1997 400(+/-10%) -3-50 0,05 0,90 1165 6,81 70 2 7542/6682 4730/1162/ 2051 400(+/-10%) -3-50 0,05 0,90 1285 6,59
Electrical Information Unit Voltage: Standby Power: Power Factor: Amps (Un) Circuit 1 Maximum Current Start Up Current Current at Eurovent Conditions Circuit 2 Maximum Current Start Up Current Current at Eurovent Conditions
*
V-Ph-Hz 400(+/-10%) -3-50 kW 0,05 -0,82
400(+/-10%) -3-50 0,05 0,90
A A A A A A
284 587 176 ----
176 414 109 176 414 109
196 414 123 196 414 123
239 587 146 196 414 123
239 587 146 239 587 146
Heating mode conditions: Condenser water heat exchanger, entering/leaving water temperature 30°C/35°C, fouling factor 0 m² K/W. Evaporator water heat exchanger, entering/leaving water temperature 10°C/7°C, fouling factor 0 m² K/W. All performances are compliant with EN14511-3 : 2013. Sound power level according to ISO9614-1. Unit is outside of the scope of AHRI Water-Cooled Water Chilling Packages Using Vapor Compression Cycle Certification Program, but is rated in accordance with AHRI Standard 550/590 (I-P) and AHRI Standard 551/591 (SI). Preliminary product data for information only. Final product data will be submitted by Carrier to Eurovent company during 2016.