WATER-TO-WATER HEAT PUMPS
30XWHV 580-1710
Options
Bacnet over IP gateway
No.
149
Description
Two-directional high-speed communication using BACnet protocol over Ethernet network (IP) Limitation of the maximum condenser leaving water temperature to 45°C
Advantages
Easy and high-speed connection by ethernet line to a building management system. Allows access to multiple unit parameters Reduced maximum power input and current absorption: power cables and protection elements can therefore be downsized Simple installation: for applications with cold water at condenser inlet (ex. groundsource, groundwater-source, superficial water-source applications) the signal permits to control a 2 or 3-way valve to maintain condenser water temperature (and so condensing pressure) at acceptable values Extended remote control capabilities (Set-point reset, ice storage end, demand limits, boiler on/off command...) Immediate customer notification of refrigerant losses to the atmosphere, allowing timely corrective actions Conformance with Swiss regulations
Use 30XWHV
580-1710
Condensing temperature limitation
150B
580-1710
Control for low condensing temperature systems
152
Output signal (0-10 V) to control the condenser water inlet valve
580-1710
Energy Management Module EMM 156
Control board with additional inputs/ outputs. See Energy Management Module option chapter 0-10 V signal to report any refrigerant leakage in the unit directly on the controlller (the leak detector itself must be supplied by the customer) Additional tests on the water heat exchangers: supply (additional of PED documents) supplementary certificates and test certifications Evaporator and suction piping sound insulation Victaulic piping connections with welded joints Victaulic piping connections with welded joints Victaulic piping connections with flanged joints Victaulic piping connections with flanged joints The compressor is covered with a thermal insulation layer Additional RFI filters on the unit power line
580-1710
Leak detection
159
580-1710
Compliance with Swiss regulations 197
580-1710
Low noise level Welded evaporator water connection kit Welded condenser water connection kit Flanged evaporator water connection kit Flanged condenser water connection kit Thermal compressor insulation EMC classification C2, as per EN 61800-3
257 266 267 268 269 271 282
3 dB(A) quiter than standard unit Easy installation Easy installation Easy installation Easy installation Prevents air humidity to condensate on the compressor surface Reduces electromagnetic interferences. Increase the variable frequency drive (VFD) immunity level according to first environment (so called, residential environment) requirements and allow its compliancy with emissions level required in category C2 Full capacity recovery in less than 5 minutes after power failure. Matches requirements of typical critical missions applications
580-1710 580-1710 580-1710 580-1710 580-1710 580-1710 580-1710
Fast Capacity Recovery
QM295
New software algorithms to allow quick restart and fast loading while preserving unit-reliability
580-1710
Carrier Connect link (BSS regions only)
298
Enabler for Carrier Connect service offer 3G router board NOTE 1: Require option 149 NOTE 2: When more than one machine is installed on site, only one of them shall be equipped with option 298 while all of them must be equipped with option 149 NOTE 3: If a CARRIER-PSM is on site, option 298 shall be integrated in the PSM while option 149 is still mandatory for each single unit.
580-1710
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
561