AIR-COOLED LIQUID CHILLERS WITH INTEGRATED HYDRONIC MODULE 30RB 602-802
Physical data
30RB units 602 672 732 802
Cooling
Full load performances* C1 C1 C1 Seasonal Efficiency* Sound Power Level Standard Unit Sound Power Level Standard Unit + Option 15 dB(A) dB(A) 95 93 95 93 96 94 96 94 Nominal capacity EER Eurovent Energy Class ESEER kW/kW kW kW/kW 606.9 2.72 C 3.97 657.3 2.68 D 3.88 711.8 2.59 D 3.75 774.4 2.58 D 3.71
Unit with Option 15LS Full load performances* C1 C1 C1 Seasonal Efficiency* Nominal capacity EER Eurovent Energy Class ESEER kW/kW dB(A) kW kW/kW 561.2 2.43 E 4.06 89 631.3 2.45 E 4.06 89 670.2 2.44 E 4.08 89 721.4 2.42 E 4.00 90
Sound Power Level Standard Unit + Options 15LS
Operating weight - standard unit† Compressors Refrigerant Capacity control Condensers Fans Quantity Total air flow (high speed) Evaporator Dimensions Length Depth Height
C1 * †
kg
4627
4873
5362
5609
Hermetic scroll, 48.3 r/s R-410A Pro-Dialog Plus All aluminium micro-channel heat exchanger (MCHE) Axial Flying Bird 4 with rotating shroud 9 l/s 40623 10 45139 11 49653 12 54167
Direct expansion, shell-and-tube
mm mm mm
5992 2253 2297
7186 2253 2297
Eurovent certified data Option 15 = compressor enclosure Option 15LS = low sound option For 30RB 162-262 units with option 280 (shell-and-tube heat exchanger) please refer to the specific product literature
Electrical data
30RB (without hydronic module)
Power circuit Nominal power supply Control circuit supply Max. power input* - circuits A + B/C Nom. current draw** - circuits A + B/C Max. start-up current*** - circuits A + B/C * ** *** kW A A V-ph-Hz
400-3-50 ± 10% 24 V, via internal transformer 191/96 251/125 535/371 191/127 251/167 535/426 255/96 334/125 645/371 255/127 334/167 645/426
602
672
732
802
Power input, compressors and fans, at the unit operating limits (saturated suction temperature 10°C, saturated condensing temperature 65°C) and nominal voltage of 400 V (data given on the unit nameplate). Nom. unit current draw at standardised Eurovent conditions: evaporator entering/leaving water temperature 12°C/7°C, outside air temperature 35°C. Maximum instantaneous start-up current at operating limit values (maximum operating current of the smallest compressor(s) + fan current + locked rotor current of the largest compressor).
Note: Units 30RB 602-802 have two electrical connection points.
C
A
R
R
I
E
R
2
0
1
6
/
2
0
1
7
149
CONTROLS
AIR TREATMENT
Cooling mode conditions: Water heat exchanger, entering/leaving temperature 12°C/7°C, fouling factor 0 m2 K/W. Outside air temperature 35°C In accordance with standard EN14511-3:2013 Weight shown is a guideline only.